COOL IDEAS SENT TO YOUR INBOX SELDOMLYOR NOTWHATEVER. A: Reply, Johanne, You'll need to remove the cell and inspect the cell for scaling. The Hayward Pool Products TCELL940 has a 4 Year Warranty period. There is not much life left in the cell, I recommend replacing both components. Most of the time the flow switch does not need to be replaced as often as the salt cell. The remedy is to reset the cellby holding down the Diagnostic buttonfor 3-5 seconds. Producing soft, silky water, that wont turn eyes red.
I have an AquaRite w/ no Cl production despite adequate salt (water test). Reply, Hi Donna,Yes the W3T-CELL-15 is the correct replacement for the GoldlineT-CELL-15. *** Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shutdown. Reply, Hi, James. Refunds (if applicable) Once your return is received and inspected, we will send you an email to notify you that we have received your returned item. * Salt Water chlorinator replacement Cell A T-Cell-9 is compatible with Aqua-Rite Software Revision 1.50 or later. You will just reach to Hayward and follow their warranty procedures. Also available is the Extended life cell with 4 year warranty. Reply, Hi, Kevin. The contractor installed a Hayward Aqualogic Goldline / Chlorinator cell that needs to be
Reply, Hi Kevin, If you need to replace the cell then you will have to replace it with the same size. Hayward is not in any way affiliated with or endorsed by those third parties. Even though cell tested ok, does this mean it is near end of life?? Hayward also makes an AquaRite low salt system that is sold in Canada (not in the US). The correct operating voltage should range between 22.0 26.0 VDCand the amp range between3.1 8.0 when using aT-CELL-15. TurboCell Extended Life Salt Chlorination Cells automatically convert pool salt into chlorine while providing in-ground pools with consistent sanitization. from Williamson, GA
Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shutdown. What cell is best and why can"t I find a Mineral Springs cell? I'm getting a message that says - Chlorinator Off No flow - Is my flow switch the problem?
Reply, Which way does the water suppose to flow through the generator? Reply, Hi Julie, this cell comes with a 15' cable, unfortunately we do not carry this cell with a longer cable. TurboCell Extended Life Salt Cell, 40,000 gallons (Expert Line), from Do I need a soft ware update? Sale items (if applicable) Only regular priced items may be refunded, unfortunately sale items cannot be refunded. Is that possible and can i change the programing myself. Products, Parts Hayward now offers a new line of Turbo Cells for their salt chlorination and controls solutions. Sorry, we were unable to perform your search at this time. All Products, View Mark
Reply, Hi,Ken. Gifts If the item was marked as a gift when purchased and shipped directly to you, youll receive a gift credit for the value of your return. Reply, Hi,Bruce. Called INYO customer support and they help diagnose the problem After determining that the T15 was way past its life expectancy I ordered a new on and system is working fine. Voltage reading varies daily from 3.7-4.2
Lights: solid low salt/inspect cell. Sanitization, Learn About Pedro B.
My second question is: Can my panel firmware be updated? My systemj is reading temperature etc but is NOT producing chlorine and the number is 1000 and decreasing every day
Find inspiration for your home and garden. Exit Settings Menu by pushing the Menu button. Turbo Cell (T-CELL-15) w/ 15' Cord -No Flow Switch Aquarite- Hayward/Goldline * Original Model - 3 year Warranty ** Obsolete Note: This is obsolete. Brand new, sealed in Manufacturer's packaging. CWH15A Compatible with Hayward Salt Cell Model No. I cannot find this part on your website. (6/12/2019), (5
This is a direct replacement, no modifications will have to be made. Reply, No you would not need a software update,the GLXCELL15 would work fine with your system here >http://www.inyopools.com/Products/02100023001296.htmThe GLXCELL15 comes without the flow switch which you would not require. The cell was very clean maybe too clean.
Products, Learn About
With savings of 50% or more over conventional chlorine costs, its not only the #1 salt chlorination cell in the world, its the best value. By next day, reading is about 900. Operation Manual for model AQL-P-4
Features & Benefits: For new or existing in-ground pools up to 40,000 gallons For use with AquaRite 900 Salt Chlorination System and compatible with Omni automation systems Generates up to 1.45 lbs. Once a shipment has been confirmed as delivered by courier or freight forwarder and your package is verified as missing, please contact us at info@poolproductscanada.ca and we can assist you.
Reply, my T-cell ur to five years old after watching your video I pulled the cell off to see if it was corroded. Reply, I have a Hayward Turbo TCELL940SWP cell, what cell is compatible to it? 2800, but drops to about 1600 or less after run cycle done. Water Features, View All please update your current version of Internet Explorer or try using a different browser. Replacing your current cell with a W3T-Cell-15 requires no reconfiguration. T cell-5. Attached please find theAqua-Rite Troubleshooting Guide andAqua-Rite Quick Reference Guide Please reference the Quick Reference Guide, Section: Display Readings, #7 - Main Circuit Board Revision. Reply, Hello Jack, any light that says "no flow" is related to your flow switch needing to be replaced. We work hard to protect your security and privacy. Profile, Create a Pool Professional If product has a -W it is a 1 year warranty only. Experience the luxurious, silky soft water that won't irritate eyes, dry out skin or cause fabrics to fade.
We are sorry. So which is the correct Hayward turbo cell model I need exactly like the one I have now. 1, (5
}. from Central Texas
I would take a chlorine reading directly at the return jet and most likely you will get a chlorine reading. Click OK to extend your time for an additional 0 minutes. Reply, Hello, what is difference between W3T-CELL-15 and Hayward TCELL940? Following, please reference the Quick Reference Guide, Section: Change Cell Size. If the firmware version is less that 1.10, the TCELL925 cannot be used. The Inspect Celland Check Salt lights should both be flashing indicating the system is reading a salinity level below 2700 PPM. BY GOLDLINE CONTROLS Is this compatible with a Hayward gold line salt water system with a firm ware of 1.4 ??
Imperial Number. If the control unit doesn't flash the flow button, can I assume the flow is good enough? If the readings stabilize in the 1-3 ppm range then you are all setotherwise make another small adjustment (up or down) to increase or decrease the chlorine level. This model is designed for the larger pools and up 40,000 gallons of water. My pool is closer to 20K gallons and in SW Florida. out of 5 stars), Reviewed By:
Independently tested - proven to deliver longer life. TurboCell Extended Life Salt Chlorination Cells automatically convert pool salt into chlorine while providing in-ground pools with consistent sanitization. It took me 2 minutes to install and it woke up and started making chlorine immediately. Hayward AquaRite 900 Salt Generator Complete 40,000 Gallons | Power Center and Extended Life TurboCell | AQR940 Parts. Dustin: 1-705-293-2233. Quick Reference Guide A local retailer may be equipped with Hayward Salt Cell Diagnostic Equipment. Please help, Hi Mike, This cell is compatible with your system. Need to replace my Goldline Chlorinator Cell 15. Products, learn Reply, Is this cell compatible with my Aqua Logic AQL-P-4 Automation Controller Main Software revision 2.87? Brief content visible, double tap to read full content. Hayward, Create a Pool Owner Manage Settings THANKS
I think I need the T-Cell-15 as my pool has bout 35k gallons.
Pool is around 20,000 gallons and I think the T5 is having a hard time keeping up, The panel is a PLPlus20G. (4/7/2012). Is there anything I can do other than replacing the cell? Please identify your Aqua-Rite current Main Circuit Board Revision. It's been 5 years almost to the month since I replaced the last one. Late or missing refunds (if applicable) If you havent received a refund yet, first check your bank account again. Regarding Extended Pool Filtration cycles, and Low Flow Rate conditions THE AMOUNT OF CHLORINE PRODUCED BY YOUR SALT CHLORINE GENERATING SYSTEM IS DEPENDENT ON THE LENGTH OF TIME THAT YOUR FILTER PUMP RUNS EVERY DAY. When pump starts, salt reading is approx. Products, Parts Reply, I have high salt in my system for the last few days now i getting a light sayin check T Cell? It also analyzed reviews to verify trustworthiness. There was a problem completing your request.
Is this overkill? Reply, Is the Hayward GLXCELL15 (T-CELL-15) the replacement cell for the 40K unit? The difference between the two cells would be the cell manufacturer (Hayward vs. Pureline) and the warranty (2-years vs. 3-years). My question is are the cells the same length and width? This item has been successfully added to your list. Profile, Create a Pool Owner Performance & security by Cloudflare. Push the Diagnostic button repeatedly until t-xx appears on the display (t-15 is the factory default). Reply. If the firmware version is less that 4.10, the TCELL925 cannot be used. Please make sure that you are posting in the form of a question. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. 0. I have heard that there may be controller incompatiblitieies. After replacing the cell is did not correct the problem. A complete listing of the available Hayward Replacement SWG Cells can be found hereHayward Chlorine Generator Replacement Cells
Reply, Hello Mark. I would like to upgrade to a T15 cell. 70.32.96.88 I have a few questions:
If not, how do I determine in I have the new software or not. I bought a Taylor K-1766 test kit, and the measured salinity was . We've seen this issue caused by a bad cell and or Main PCB. on HAYWARD TCELL925 Aqua Rite Up To 25K Gallons Instruction Manual, Hayward In Ground Pool/Spa Gas Heaters User Manual, HAYWARD HP31005T Pool Heat Pump Owners Manual. Your email address will not be published. September 11, 2020 NOTICE: Because Hayward cannot control the quality of products sold by unauthorized sellers, our limited warranties apply only to a product that was purchased from Hayward or a Hayward authorized seller, unless . I would suggest having it tested at a local pool retailer. Could you send us a few photos of the cell itselfand the label on it? Profile, Create a Pool ${cardName} not available for the seller you chose. Please try again later. The controller will have the proper Cell Voltage22-32 VDCand Cell Amps3.1 - 8.0 Amps. Cleaners, Learn About Can I use a T-3 instead since the cost is so much lower? Comment * document.getElementById("comment").setAttribute("id","af0aaae69eac2cf3053ed376561dab5b");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment.
***Replacement Cell Only*** Extended Life TurboCell - up to 40, 000 gallons / Item # TCELL940 Product Description: The SwimPure Extreme Salt Cell works with the Hayward SwimPure Extreme Salt Generator. This is truly a great product. Reply, I have a T-Cell-15, My pool control panel says "Pool Chlorinator 30%" "Chlorinator Off - High Salt Amps"
Please try again. The T15 cell and the CLXCELL15 are the same cell, the model name is T15 and the part # is GLXCELL15
Reply, I have an Aqua logic AQL-P-4 control panel. APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Water Features Solar Safety HAYWARD TCELL925 Aqua Rite Up To 25K Gallons, Rite Indoor & Outdoor Rite Power Burner Fired Boilers User Manual, AQUA LUNG DrySuit A6-Vecto Instruction Manual, AQR (AquaRite all 2009 or later) firmware version 1.5 or later, AQR-PRO (AquaRite Pro) operating with firmware 1.10 or later, PL-P-4 (ProLogic P4) operating with firmware 4.10 or later, PL-PS-x (ProLogic PS) operating with firmware 4.10 or later.